浏览全部资源
扫码关注微信
1.太原理工大学电气与动力工程学院,山西省太原市 030024
2.煤电清洁智能控制教育部重点实验室(太原理工大学),山西省太原市 030024
秦雪雪(2001—),女,硕士研究生,主要研究方向:数据中心的能量管理。E-mail:xuexueqin2023@163.com
李泽宁(1994—),男,通信作者,博士,讲师,主要研究方向:城市配电网负荷恢复、集成智能楼宇的主动配电网优化运行。E-mail:lizening@tyut.edu.cn
薛屹洵(1993—),男,博士,教授,主要研究方向:综合能源系统运行与规划。E-mail:xueyixun@tyut.edu.cn
收稿:2024-07-06,
修回:2025-01-14,
网络出版:2025-05-12,
纸质出版:2025-06-10
移动端阅览
秦雪雪,李泽宁,薛屹洵等.计及建筑热动态特性的数据中心时空协调两阶段鲁棒优化方法[J].电力系统自动化,2025,49(11):59-69.
QIN Xuexue,LI Zening,XUE Yixun,et al.Two-stage Robust Optimization Method for Spatio-Temporal Coordination of Data Center Considering Thermal Dynamic Characteristics of Buildings[J].Automation of Electric Power Systems,2025,49(11):59-69.
秦雪雪,李泽宁,薛屹洵等.计及建筑热动态特性的数据中心时空协调两阶段鲁棒优化方法[J].电力系统自动化,2025,49(11):59-69. DOI: 10.7500/AEPS20240706001.
QIN Xuexue,LI Zening,XUE Yixun,et al.Two-stage Robust Optimization Method for Spatio-Temporal Coordination of Data Center Considering Thermal Dynamic Characteristics of Buildings[J].Automation of Electric Power Systems,2025,49(11):59-69. DOI: 10.7500/AEPS20240706001.
为实现数据中心的经济灵活运行,提出一种计及建筑热动态特性的数据中心时空协调两阶段鲁棒优化方法。首先,基于数据中心建筑的热动态特性与云用户负载的差异化实时性需求,构建考虑服务器运行环境温度的数据中心云用户负载时空协调数学模型。其次,考虑到常规负载与室外温度的不确定性,提出计及数据中心建筑热动态特性的数据中心两阶段鲁棒优化方法,通过设置不确定性调节参数灵活调整优化保守程度。然后,采用列与约束生成(C&CG)算法迭代求解得到原问题的最优解。最后,通过算例分析对所提方法进行验证。结果表明,所提方法可在保障服务器运行环境温度的前提下,充分挖掘云用户负载时空灵活性和空调制冷灵活性的协同潜力,显著提升了数据中心运行的经济性,有效提高了系统抵御风险的能力。
To achieve the economic and flexible operation of data centers
a two-stage robust optimization method for spatio-temporal coordination of data center considering thermal dynamic characteristics of buildings is proposed. Firstly
based on the thermal dynamic characteristics of data center buildings and the differentiated real-time requirements of cloud user loads
a spatio-temporal coordination mathematical model of cloud user loads in data centers considering the operation environment temperature of servers is constructed. Secondly
considering the uncertainties of conventional load and outdoor temperature
a two-stage robust optimization method for data center considering the thermal dynamic characteristics of data center buildings is proposed. The degree of optimization conservatism is flexibly adjusted by setting uncertainty adjustment parameters. Then
the column and constraint generation (C&CG) algorithm is adopted for iterative solution to obtain the optimal solution to the original problem. Finally
the proposed method is verified through case analysis. The results show that the proposed method can fully tap the synergy potential of the spatio-temporal flexibility of cloud user loads and the flexibility of air conditioning cooling on the premise of ensuring the operation environment temperature of the server
significantly improve the economy of data center operation
and effectively enhance the system ability to resist risks.
KOOT M , WIJNHOVEN F . Usage impact on data center electricity needs: a system dynamic forecasting model [J]. Applied Energy , 2021 , 291 : 116798 .
LIU Y N , WEI X X , XIAO J Y , et al . Energy consumption and emission mitigation prediction based on data center traffic and PUE for global data centers [J]. Global Energy Interconnection , 2020 , 3 ( 3 ): 272 - 282 .
DING Z H , CAO Y J , XIE L Y , et al . Integrated stochastic energy management for data center microgrid considering waste heat recovery [J]. IEEE Transactions on Industry Applications , 2019 , 50 ( 3 ): 2198 - 2207 .
WANG J J , DENG H D , LIU Y , et al . Coordinated optimal scheduling of integrated energy system for data center based on computing load shifting [J]. Energy , 2023 , 267 : 126585 .
BENBLIDIA M A , BRIK B , ESSEGHIR M , et al . Power allocation and energy cost minimization in cloud data centers microgrids: a two-stage optimization approach [J]. IEEE Access , 2022 , 10 : 66213 - 66226 .
CHEN M , GAO C W , SHAHIDEHPOUR M , et al . Internet data center load modeling for demand response considering the coupling of multiple regulation methods [J]. IEEE Transactions on Smart Grid , 2021 , 12 ( 3 ): 2060 - 2076 .
WAN J X , DUAN Y D , GUI X , et al . Safecool: safe and energy-efficient cooling management in data centers with model-based reinforcement learning [J]. IEEE Transactions on Emerging Topics in Computational Intelligence , 2023 , 7 ( 6 ): 1621 - 1635 .
朱介北 , 杨顺坡 , 俞露杰 , 等 . 数据中心制冷系统即时消纳可再生能源的建模和变温控制 [J]. 电力系统自动化 , 2022 , 46 ( 20 ): 13 - 22 .
ZHU Jiebei , YANG Shunpo , YU Lujie , et al . Modeling and variable temperature control for instant consumption of renewable energy in data center cooling systems [J]. Automation of Electric Power Systems , 2022 , 46 ( 20 ): 13 - 22 .
NADJAHI C , LOUAHLIA H , LEMASSON S . A review of thermal management and innovative cooling strategies for data center [J]. Sustainable Computing: Informatics and Systems , 2018 , 19 : 14 - 28 .
ZHANG H F , XU T , WU H Y , et al . Risk-based stochastic day-ahead operation for data centre virtual power plants [J]. IET Renewable Power Generation , 2019 , 13 ( 10 ): 1660 - 1669 .
ZHOU Y Z , SHAHIDEHPOUR M , WEI Z N , et al . Distributionally robust unit commitment in coordinated electricity and district heating networks [J]. IEEE Transactions on Power Systems , 2020 , 35 ( 3 ): 2155 - 2166 .
YANG J , SU C Q . Robust optimization of microgrid based on renewable distributed power generation and load demand uncertainty [J]. Energy , 2021 , 223 : 120043 .
CHEN T Y , ZHANG Y , WANG X , et al . Robust workload and energy management for sustainable data centers [J]. IEEE Journal on Selected Areas in Communications , 2016 , 34 ( 3 ): 651 - 664 .
JAWAD M , QURESHI M B , KHAN M U S , et al . A robust optimization technique for energy cost minimization of cloud data centers [J]. IEEE Transactions on Cloud Computing , 2021 , 9 ( 2 ): 447 - 460 .
LIAN Y C , LI Y Z , ZHAO Y , et al . Robust multi-objective optimization for islanded data center microgrid operations [J]. Applied Energy , 2023 , 330 : 120344 .
GHAMKHARI M , WIERMAN A , MOHSENIAN-RAD H . Energy portfolio optimization of data centers [J]. IEEE Transactions on Smart Grid , 2017 , 8 ( 4 ): 1898 - 1910 .
韩冰冰 . 数据中心可再生能源和余热利用现状 [J]. 智能建筑 , 2020 , 5 : 47 - 53 .
HAN Bingbing . Present situation of renewable energy and waste heat utilization in data center [J]. Intelligent Building , 2020 , 5 : 47 - 53 .
王丹阳 , 张沈习 , 程浩忠 , 等 . 考虑数据中心用能时空可调的电-气互联综合能源系统分布式光伏最大准入容量计算 [J]. 电力系统及其自动化学报 , 2023 , 35 ( 2 ): 121 - 131 .
WANG Danyang , ZHANG Shenxi , CHENG Haozhong , et al . Calculation of maximum allowable access capacity of distributed photovoltaic in electricity-gas integrated energy system considering spatio-temporal adjustability of energy consumption by data centers [J]. Proceedings of the CSU-EPSA , 2023 , 35 ( 2 ): 121 - 131 .
LI J , LI Z Y , REN K , et al . Towards optimal electric demand management for Internet data centers [J]. IEEE Transactions on Smart Grid , 2012 , 3 ( 1 ): 183 - 192 .
CHU J J , HUANG X . Research status and development trends of evaporative cooling air-conditioning technology in data centers [J]. Energy and Built Environment , 2023 , 4 ( 1 ): 86 - 110 .
刘一欣 , 郭力 , 王成山 . 微电网两阶段鲁棒优化经济调度方法 [J]. 中国电机工程学报 , 2018 , 38 ( 14 ): 4013 - 4022 .
LIU Yixin , GUO Li , WANG Chengshan . Economic dispatch of microgrid based on two stage robust optimization [J]. Proceedings of the CSEE , 2018 , 38 ( 14 ): 4013 - 4022 .
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621