The performance of primary frequency control has a significant influence on the power system stability and power quality. There are plenty of heat stored in the heat supply network of combined heat and power(CHP)units
which can improve the unit load-following performance without affecting the heat demand in a short time period. The static and dynamic model of heat extraction adjustment together with heat-power coupling model are set up. A new load-change idea according to the way of “rapid heat extraction adjustment
accurate fuel supply following
and steady heat extraction recovery” is proposed. A new load-change control strategy combining heat extraction adjustment and traditional coordinated control is given. A 330 MW CHP unit is taken as an example to verify the idea
and the results show that the strategy proposed can shorten the dead time of load response
quicken the load-change rate