The three-dimensional space vector pulse width modulation (3D-SVPWM) control strategy for suppressing common-mode voltage of three-phase four-bridge inverter is analyzed. Because the common mode voltage generated from the high power convertor system is easy to damage the load such as motor
and affect the power quality of the power supply
an optimized 3D-SVPWM control strategy is proposed. Firstly
the topology of three-phase four-bridge inverter is described
and the reason of generating the common mode voltage is given. Then
according to the traditional 3D-SVPWM control strategy
two converse non-zero vectors near the reference vector are selected to replace the zero vectors. Finally
the modeling and simulation are carried out through MATLAB/Simulink and the results show that the improved control strategy is not affected by the changes of load balance status. Moreover
without changing the DC voltage utilization
the common-mode voltage can be effectively decreased to realize active suppression.