In order to solve the problems of low frequency noise
voltage drift and the measurement accuracy in the integral part of the electronic current transformer measurement and improve the engineering practicability of air-core coil electronic current transformer
an improved high-precision digital integral algorithm is proposed based on the principle of variable step integral algorithm. Compared to some other improved integral transfer functions
the error of the frequency characteristic and the ideal integral is much smaller. Meanwhile
the algorithm has the advantages of moderate sampling rate
less amount of calculation and high precision. The simulation results show that the improved algorithm has good performance and better ability of resisting noise and voltage drift.