To solve the problem of unstable output voltage of inductively coupled power transfer system (ICPT) subject to disturbance or great load changes
the energy and efficiency of two different compensation topology structures are studied. The output voltage
output power
output efficiency
frequency stability
and load adaptability of the parallel-series (PS) topology and the series-series (SS) topology are also dealt with. Based on the variable structure mode
the method employing different topologies for different loads is given. The switching prerequisite is analyzed in detail and the methods of ensuring safety and effectiveness of switching are recommended. In order to validate the effectiveness of the variable structure mode
two greatly different loads are adopted with their output voltage measured in voltage and current mode ICPT system
respectively. The results show that the variable structure mode is suitable for constant-voltage ICPT system whose load is greatly changed. This work is supported by National Natural Science Foundation of China (No. 51277192).