Effects of Location,Size and Number of Wind Turbine Receptorson Blade Lightning Protection
暂无标题
电力系统自动化2012年36卷第8期 页码:122-127
作者机构:
Faculty of Electrical & Computer Engineering,Shahid Beheshti University,Tehran198396,Iran,3113
作者简介:
基金信息:
DOI:
中图分类号:
纸质出版日期:2012
稿件说明:
移动端阅览
Hossein Kazemi KAREGAR, Hossein BAGHERIAN. Effects of Location,Size and Number of Wind Turbine Receptorson Blade Lightning Protection[J]. 电力系统自动化, 2012,36(8):122-127.
Hossein Kazemi KAREGAR, Hossein BAGHERIAN. Effects of Location,Size and Number of Wind Turbine Receptorson Blade Lightning Protection[J]. 电力系统自动化, 2012,36(8):122-127.DOI:
DOI:
Effects of Location,Size and Number of Wind Turbine Receptorson Blade Lightning Protection
摘要
Electric and magnetic fields generated by lightning cause a serious hazard to various systems.Now windturbine installations with higher power capacity are increasing.Higher power capacity requires higher height and sothere is more probability of lightning strike.Blades are the most probable components to be struck by lightning. The most common lightning protection system for the blades consists of several metallic receptors on the bladesurface.Those are connected to the ground by metallic down-conductors placed inside the blade shell.This paperstudies effects of the receptor configurations on protecting the blade against lightning strike.For this purpose,ananalysis procedure based on finite element method(FEM)in COMSOL Multiphysics software environment is used. The voltage distribution around the blade is simulated for various configurations of receptors.The best configurationis presented.Simulations are performed on the blade model of a special wind turbine,which isVESTAS V47”.
Abstract
Electric and magnetic fields generated by lightning cause a serious hazard to various systems.Now windturbine installations with higher power capacity are increasing.Higher power capacity requires higher height and sothere is more probability of lightning strike.Blades are the most probable components to be struck by lightning. The most common lightning protection system for the blades consists of several metallic receptors on the bladesurface.Those are connected to the ground by metallic down-conductors placed inside the blade shell.This paperstudies effects of the receptor configurations on protecting the blade against lightning strike.For this purpose,ananalysis procedure based on finite element method(FEM)in COMSOL Multiphysics software environment is used. The voltage distribution around the blade is simulated for various configurations of receptors.The best configurationis presented.Simulations are performed on the blade model of a special wind turbine,which isVESTAS V47”.