A Dynamic Reactive Power Control for DFIG Wind Turbines andIts Impacts on Distribution Protections
暂无标题
电力系统自动化2012年36卷第8期 页码:185-190
作者机构:
College of Electric Power,South China University of Technology,Guangzhou,China,510640
作者简介:
基金信息:
国家重点基础研究发展计划(“973计划”),粤港关键领域重点突破项目
DOI:
中图分类号:
纸质出版日期:2012
稿件说明:
移动端阅览
Haifeng LI, Xiang GAO, Gang WANG, 等. A Dynamic Reactive Power Control for DFIG Wind Turbines andIts Impacts on Distribution Protections[J]. 电力系统自动化, 2012,36(8):185-190.
Haifeng LI, Xiang GAO, Gang WANG, 等. A Dynamic Reactive Power Control for DFIG Wind Turbines andIts Impacts on Distribution Protections[J]. 电力系统自动化, 2012,36(8):185-190.DOI:
DOI:
A Dynamic Reactive Power Control for DFIG Wind Turbines andIts Impacts on Distribution Protections
摘要
With the increasing penetration of distributed generations(DGs)into power grids,the fault ride-throughability of DG is attracting more and more attention.Recent grid codes require a DG to maintain its connection withthe grid during grid faults and to play an active role in the recovery of grid voltage.This paper chooses the doubly- fed induction generator(DFIG)as the typical wind turbine for study.Firstly,a dynamic reactive power controlstrategy is proposed to improve the fault ride-through characteristic of a DFIG.The contributions of a DFIG to thefault current under the dynamic reactive power control and the Crowbar control are analyzed and compared based onthe mathematical expressions and control behaviors.The impacts of a DFIG under two control strategies ondistribution protections are discussed.Studies show that although a DFIG under the dynamic reactive power controlprovides more fault current component than one under the Crowbar control,its impacts on distribution protectionsare acceptable.Finally,a10kV distribution network with a DFIG is simulated in PowerFactory DIgSILENT.Thesimulation results prove the correctness of above theoretical analysis.
Abstract
With the increasing penetration of distributed generations(DGs)into power grids,the fault ride-throughability of DG is attracting more and more attention.Recent grid codes require a DG to maintain its connection withthe grid during grid faults and to play an active role in the recovery of grid voltage.This paper chooses the doubly- fed induction generator(DFIG)as the typical wind turbine for study.Firstly,a dynamic reactive power controlstrategy is proposed to improve the fault ride-through characteristic of a DFIG.The contributions of a DFIG to thefault current under the dynamic reactive power control and the Crowbar control are analyzed and compared based onthe mathematical expressions and control behaviors.The impacts of a DFIG under two control strategies ondistribution protections are discussed.Studies show that although a DFIG under the dynamic reactive power controlprovides more fault current component than one under the Crowbar control,its impacts on distribution protectionsare acceptable.Finally,a10kV distribution network with a DFIG is simulated in PowerFactory DIgSILENT.Thesimulation results prove the correctness of above theoretical analysis.