Analysis of Short-circuit Characteristics and Calculation ofSteady-state Short-circuit Current for DFIG Wind Turbine
暂无标题
电力系统自动化2012年36卷第8期 页码:115-121
作者机构:
State Key Laboratory of Power Transmission Equipment and System Security Chongqing University,Chongqing,China,400030
作者简介:
基金信息:
高等学校学科创新引智计划资助;中央高校基本科研业务费资助;重庆大学输配电国家重点实验室资助重点项目
DOI:
中图分类号:
纸质出版日期:2012
稿件说明:
移动端阅览
Xiaofu XIONG, Jinxin OUYANG. Analysis of Short-circuit Characteristics and Calculation ofSteady-state Short-circuit Current for DFIG Wind Turbine[J]. 电力系统自动化, 2012,36(8):115-121.
Xiaofu XIONG, Jinxin OUYANG. Analysis of Short-circuit Characteristics and Calculation ofSteady-state Short-circuit Current for DFIG Wind Turbine[J]. 电力系统自动化, 2012,36(8):115-121.DOI:
DOI:
Analysis of Short-circuit Characteristics and Calculation ofSteady-state Short-circuit Current for DFIG Wind Turbine
摘要
Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required toremain grid-connection during faults,the short-circuit current contributed by the generation has become a significantissue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied tothe DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning, protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetricshort-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.Anew method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions. The time-domain simulations are conducted to verify the accuracy of the proposed method.
Abstract
Large-scale doubly-fed induction generator(DFIG)wind turbines are connected to the grid and required toremain grid-connection during faults,the short-circuit current contributed by the generation has become a significantissue.However,the traditional calculation methods aiming at synchronous generators cannot be directly applied tothe DFIG wind turbines.A new method is needed to calculate the short-circuit current required by the planning, protection and control of the power grid.The short-circuit transition of DFIG under symmetrical and asymmetricshort-circuit conditions are mathematically deduced,and the short-circuit characteristics of DFIG are analyzed.Anew method is proposed to calculate the steady-state short-circuit current of DFIG based on the derived expressions. The time-domain simulations are conducted to verify the accuracy of the proposed method.