浏览全部资源
扫码关注微信
1.中国石油大学(华东)新能源学院,山东省青岛市 266580
2.国网陕西省电力公司电力科学研究院,陕西省西安市 710100
3.山东科汇电力自动化股份有限公司,山东省济南市 250101
4.山东理工大学智能电网研究院,山东省淄博市 255049
Received:18 December 2022,
Revised:2023-06-05,
Published Online:31 August 2023,
Published:10 October 2023
移动端阅览
亓志滨,薛永端,刘健等.跨线相继接地故障暂态特征与暂态选线方法适用性[J].电力系统自动化,2023,47(19):156-165.
QI Zhibin,XUE Yongduan,LIU Jian,et al.Transient Characteristics of Cross-line Successive Grounding Faults and Applicability of Transient Line Selection Methods[J].Automation of Electric Power Systems,2023,47(19):156-165.
亓志滨,薛永端,刘健等.跨线相继接地故障暂态特征与暂态选线方法适用性[J].电力系统自动化,2023,47(19):156-165. DOI: 10.7500/AEPS20221218002.
QI Zhibin,XUE Yongduan,LIU Jian,et al.Transient Characteristics of Cross-line Successive Grounding Faults and Applicability of Transient Line Selection Methods[J].Automation of Electric Power Systems,2023,47(19):156-165. DOI: 10.7500/AEPS20221218002.
目前,针对小电流接地系统单相接地故障特征的理论分析已经成熟,但对两点相继接地故障暂态特征的研究较少,其与普通单相接地故障的暂态电气量差异以及已有暂态选线方法的适用性尚不明确。针对小电流接地系统跨线同名相和异名相两点相继接地故障暂态特征问题,建立了后发低阻接地故障暂态等值电路,对故障线路暂态特征进行理论分析并与其单独接地时暂态电气量进行了比较
得到了故障线路暂态特征随不同故障条件(过渡电阻、线路电感、系统对地电容、后发故障相)的变化规律
证明了部分暂态选线方法不再适用于后发接地故障并提出了基于连续检测的选线方法。最后,通过数字仿真和现场数据验证了文中分析结果的正确性。
At present
the theoretical analysis of single-phase grounding fault characteristics for non-solidly grounded systems has been mature
but there are few studies on the transient characteristics of two-point successive grounding faults. The differences in transient electrical quantities between cross-line successive grounding faults and normal single-line grounding faults and the applicability of existing transient line selection methods are still unclear. In order to solve the problem of transient characteristics of two-point successive grounding faults of the same and different phases in a non-solidly grounded system
a transient equivalent circuit of subsequent low-impedance grounding fault is established. The transient characteristics of fault lines are analyzed and compared with the transient electrical quantities of normal single-phase grounding fault. The transient characteristics of fault lines vary with different fault conditions
such as transition resistance
inductance
capacitance to ground
and successive fault phase. It is proven that the partial transient line selection methods are no longer suitable for subsequent grounding faults and a line selection method based on continuous detection is proposed. Finally
the correctness of the analysis results is verified by digital simulation and field data.
徐丙垠 , 薛永端 , 冯光 , 等 . 配电网接地故障保护若干问题的探讨 [J]. 电力系统自动化 , 2019 , 43 ( 20 ): 1 - 7 .
XU Bingyin , XUE Yongduan , FENG Guang , et al . Discussion on several problems of earthing fault protection in distribution network [J]. Automation of Electric Power Systems , 2019 , 43 ( 20 ): 1 - 7 .
徐丙垠 , 李天友 , 薛永端 . 配电网继电保护与自动化 [M]. 北京 : 中国电力出版社 , 2017 .
XU Bingyin , LI Tianyou , XUE Yongduan . Relaying protection and automation of distribution networks [M]. Beijing : China Electric Power Press , 2017 .
王文轩 , 程力涵 , 樊轶 , 等 . 不依赖零序电压的配电站所接地故障识别方法 [J]. 电力系统自动化 , 2021 , 45 ( 9 ): 122 - 129 .
WANG Wenxuan , CHENG Lihan , FAN Yi , et al . Identification methohd of grounding fault for distribution station independent of zero-sequence voltage [J]. Automation of Electric Power Systems , 2021 , 45 ( 9 ): 122 - 129 .
涂春鸣 , 侯玉超 , 郭祺 , 等 . 计及配电网线路阻抗影响的自适应接地故障消弧控制策略 [J]. 电力系统自动化 , 2022 , 46 ( 8 ): 163 - 171 .
TU Chunming , HOU Yuchao , GUO Qi , et al . Adaptive arc suppression control strategy for grounding fault considering influence of line impedance in distribution network [J]. Automation of Electric Power Systems , 2022 , 46 ( 8 ): 163 - 171 .
曾祥君 , 黄慧 , 喻锟 , 等 . 基于柔性调控零序电压的配电网高阻接地及单相断线故障的选相方法 [J]. 电力系统保护与控制 , 2022 , 50 ( 3 ): 9 - 18 .
ZENG Xiangjun , HUANG Hui , YU Kun , et al . Voltage phase selection method for high resistance grounding and a single-phase disconnection fault of a distribution network based on flexible control of zero-sequence voltage [J]. Power System Protection and Control , 2022 , 50 ( 3 ): 9 - 18 .
李振兴 , 万佳灵 , 王新 , 等 . 基于中值电阻投切的故障选线与定位新方法 [J]. 电力系统保护与控制 , 2021 , 49 ( 7 ): 57 - 65 .
LI Zhenxing , WAN Jialing , WANG Xin , et al . A novel method of fault line selection and section location based on the input and cutoff of medium resistance [J]. Power System Protection and Control , 2021 , 49 ( 7 ): 57 - 65 .
陈锐 . 基于快速消弧线圈的扰动法选线分析及应用 [J]. 电力系统保护与控制 , 2008 , 36 ( 20 ): 41 - 44 .
CHEN Rui . Analysis with applications on selecting single-phase line faulting by disturbance method based on fast-responding arc suppression coil [J]. Power System Protection and Control , 2008 , 36 ( 20 ): 41 - 44 .
王建元 , 张峥 . 基于注入信号与小波能量的小电流接地故障选线研究 [J]. 电测与仪表 , 2018 , 55 ( 5 ): 28 - 32 .
WANG Jianyuan , ZHANG Zheng . Research of fault line selection in small current grounding system based on injected signal and wavelet energy [J]. Electrical Measurement & Instrumentation , 2018 , 55 ( 5 ): 28 - 32 .
张利 , 杨鹏 , 司冬梅 , 等 . 基于零序功率方向的中性点不接地系统在线故障定位 [J]. 电力系统自动化 , 2008 , 32 ( 17 ): 79 - 82 .
ZHANG Li , YANG Peng , SI Dongmei , et al . Online fault location of neutral point ungrounded distribution network based on zero-sequence power direction [J]. Automation of Electric Power Systems , 2008 , 32 ( 17 ): 79 - 82 .
郭清滔 , 吴田 . 小电流接地系统故障选线方法综述 [J]. 电力系统保护与控制 , 2010 , 38 ( 2 ): 146 - 152 .
GUO Qingtao , WU Tian . Survey of the methods to select fault line in neutral point ineffectively grounded power system [J]. Power System Protection and Control , 2010 , 38 ( 2 ): 146 - 152 .
LIN X N , SUN J W , KURSAN I , et al . Zero-sequence compensated admittance based faulty feeder selection algorithm used for distribution network with neutral grounding through Peterson-coil [J]. International Journal of Electrical Power & Energy Systems , 2014 , 63 : 747 - 752 .
王建元 , 朱永涛 , 秦思远 . 基于方向行波能量的小电流接地系统故障选线方法 [J]. 电工技术学报 , 2021 , 36 ( 19 ): 4085 - 4096 .
WANG Jianyuan , ZHU Yongtao , QIN Siyuan . Fault line selection method for small current grounding system based on directional traveling wave energy [J]. Transactions of China Electrotechnical Society , 2021 , 36 ( 19 ): 4085 - 4096 .
方毅 , 薛永端 , 宋华茂 , 等 . 谐振接地系统高阻接地故障暂态能量分析与选线 [J]. 中国电机工程学报 , 2018 , 38 ( 19 ): 5636 - 5645 .
FANG Yi , XUE Yongduan , SONG Huamao , et al . Transient energy analysis and faulty feeder identification method of high impedance fault in the resonant grounding system [J]. Proceedings of the CSEE , 2018 , 38 ( 19 ): 5636 - 5645 .
LIU P H , HUANG C . Detecting single-phase-to-ground fault event and identifying faulty feeder in neutral ineffectively grounded distribution system [J]. IEEE Transactions on Power Delivery , 2018 , 33 ( 5 ): 2265 - 2273 .
管廷龙 , 薛永端 , 徐丙垠 . 基于故障相电压极化量的谐振接地系统高阻故障方向检测方法 [J]. 电力系统保护与控制 , 2020 , 48 ( 23 ): 73 - 81 .
GUAN Tinglong , XUE Yongduan , XU Bingyin . Method for detecting high-impedance fault direction in a resonant grounding system based on voltage polarization of the fault phase [J]. Power System Protection and Control , 2020 , 48 ( 23 ): 73 - 81 .
金鑫 , 薛永端 , 彭振华 , 等 . 仅利用零序电流的谐振接地系统接地故障方向算法 [J]. 电力系统自动化 , 2020 , 44 ( 9 ): 164 - 170 .
JIN Xin , XUE Yongduan , PENG Zhenhua , et al . Grounding fault direction algorithm using zero-sequence current in resonant grounding system [J]. Automation of Electric Power Systems , 2020 , 44 ( 9 ): 164 - 170 .
王尊贤 , 武守远 , 栾晓明 . 基于虚拟能量变化率的谐振接地系统高阻接地故障选线方法 [J]. 电力系统自动化 , 2022 , 46 ( 3 ): 137 - 146 .
WANG Zunxian , WU Shouyuan , LUAN Xiaoming . Fault line selection method for high-impedance grounding fault of resonant grounded system based on change rate of virtual energy [J]. Automation of Electric Power Systems , 2022 , 46 ( 3 ): 137 - 146 .
吴凤翔 , 顾兆雄 . 小电流接地系统两点接地故障仿真分析 [J]. 上海电力大学学报 , 2020 , 36 ( 6 ): 524 - 528 .
WU Fengxiang , GU Zhaoxiong . Analysis of the cross-country grounded fault in the low current grounded system [J]. Journal of Shanghai University of Electric Power , 2020 , 36 ( 6 ): 524 - 528 .
薛永端 , 亓志滨 , 蔡卓远 , 等 . 基于零序导纳变化的跨线异名相两点相继接地故障检测 [J]. 电力系统自动化 , 2023 , 47 ( 7 ): 174 - 183 .
XUE Yongduan , QI Zhibin , CAI Zhuoyuan , et al . Cross-line different-phase two-point successive grounding fault detection based on change of zero-sequence admittance [J]. Automation of Electric Power Systems , 2023 , 47 ( 7 ): 174 - 183 .
张宗熙 , 薛永端 , 董立明 , 等 . 不接地系统同名相两点接地故障工频特征及选线 [J]. 电力系统及其自动化学报 , 2022 , 34 ( 9 ): 9 - 16 .
ZHANG Zongxi , XUE Yongduan , DONG Liming , et al . Power frequency characteristics and line selection of two-point grounding fault in the same phase in ungrounded system [J]. Proceedings of the CSU-EPSA , 2022 , 34 ( 9 ): 9 - 16 .
刘映彤 , 黄纯 , 袁静泊 , 等 . 谐振接地系统两点同相接地故障暂态特征及选线 [J]. 中国电力 , 2022 , 55 ( 10 ): 62 - 70 .
LIU Yingtong , HUANG Chun , YUAN Jingbo , et al . Transient characteristics and line selection of two-point grounding fault in resonant grounding system [J]. Electric Power , 2022 , 55 ( 10 ): 62 - 70 .
薛永端 , 李娟 , 徐丙垠 . 中性点经消弧线圈接地系统小电流接地故障暂态等值电路及暂态分析 [J]. 中国电机工程学报 , 2015 , 35 ( 22 ): 5703 - 5714 .
XUE Yongduan , LI Juan , XU Bingyin . Transient equivalent circuit and transient analysis of single-phase earth fault in arc suppression coil grounded system [J]. Proceedings of the CSEE , 2015 , 35 ( 22 ): 5703 - 5714 .
亓志滨 , 田君杨 , 薛永端 , 等 . 不接地系统异名相两点接地故障工频电气量及其对选线的影响分析 [J]. 电工技术学报 , 2023 , 38 ( 13 ): 3539 - 3551 .
QI Zhibin , TIAN Junyang , XUE Yongduan , et al . Analysis of power frequency electrical quantity and line selection applicability for two-point grounding faults occurring on different phases in isolated neutral system [J]. Transactions of China Electrotechnical Society , 2023 , 38 ( 13 ): 3539 - 3551 .
李福寿 . 中性点非有效接地电网的运行 [M]. 北京 : 水利电力出版社 , 1993 .
LI Fushou . Operation of neutral point ineffective grounding power grid [M]. Beijing : Water Resources and Electric Power Press , 1993 .