浏览全部资源
扫码关注微信
1.国家电能变换与控制工程技术研究中心(湖南大学),湖南省长沙市 410082
2.长沙理工大学电气与信息工程学院,湖南省长沙市 410082
3.珠海万力达电气自动化有限公司,广东省珠海市 519000
Received:23 July 2021,
Revised:2021-11-22,
Published Online:15 March 2022,
Published:25 April 2022
移动端阅览
涂春鸣,侯玉超,郭祺等.计及配电网线路阻抗影响的自适应接地故障消弧控制策略[J].电力系统自动化,2022,46(8):163-171.
TU Chunming,HOU Yuchao,GUO Qi,et al.Adaptive Arc Suppression Control Strategy for Grounding Fault Considering Influence of Line Impedance in Distribution Network[J].Automation of Electric Power Systems,2022,46(8):163-171.
涂春鸣,侯玉超,郭祺等.计及配电网线路阻抗影响的自适应接地故障消弧控制策略[J].电力系统自动化,2022,46(8):163-171. DOI: 10.7500/AEPS20210723008.
TU Chunming,HOU Yuchao,GUO Qi,et al.Adaptive Arc Suppression Control Strategy for Grounding Fault Considering Influence of Line Impedance in Distribution Network[J].Automation of Electric Power Systems,2022,46(8):163-171. DOI: 10.7500/AEPS20210723008.
接地故障电弧可靠熄灭是配电网安全运行的重要保障,针对现有有源消弧方法很难同时兼顾高阻与低阻接地故障消弧需求的问题,文中提出一种计及配电网线路阻抗影响的自适应接地故障主动调控方法。首先,推导了故障点残压、残流随接地电阻和故障距离的变化规律,证明电压消弧受线路阻抗影响的机理。其次,通过对比配电网接地故障电流完全消弧与未完全消弧时线路特征参量的差异,提出将故障相的负荷总电流与消弧变流器并网点线路电流差量转换为故障点残压补偿量,以抵消线路压降对电压消弧的影响。通过分析控制系统传递函数与波特图,证明该控制方法具有较强的稳定性和对线路参数变化的适应性。最后,通过MATLAB/Simulink仿真以及RT-LAB硬件在环实验,验证所提消弧控制策略的可靠性与可行性。
The reliable extinction of grounding fault arc is an important guarantee for the safe operation of the distribution network. In view of the problem that it is difficult for the existing active arc suppression methods to take into account the arc suppression requirements of high-resistance and low-resistance grounding faults at the same time
this paper proposes an adaptive active regulation method of grounding fault considering the influence of line impedance of distribution network. Firstly
the variation law of residual voltage and residual current at the fault point with the grounding resistance and the fault distance is deduced
and the mechanism of voltage arc suppression affected by line impedance is proven. Secondly
by comparing the difference of line characteristic parameters between complete arc suppression and incomplete arc suppression of grounding fault current in the distribution network
it is proposed to convert the difference between the total load current of fault phase and the line current of the connection point of the arc suppression converter into residual voltage compensation at the fault point
to offset the influence of line voltage drop on voltage arc suppression. By analyzing the transfer function and Bode diagram of the control system
it is proven that the control method has strong stability and adaptability to the change of line parameters. Finally
the reliability and feasibility of the proposed arc suppression control strategy are verified by MATLAB/Simulink simulation and RT-LAB hardware-in-loop experiment.
蒋顺平 , 丁勇 , 石祥建 , 等 . 位移过电压抑制转接地故障消弧的柔性电源控制方法 [J]. 电力系统自动化 , 2021 , 45 ( 20 ): 140 - 147 .
JIANG Shunping , DING Yong , SHI Xiangjian , et al . Control method of displacement overvoltage suppression switching to ground fault arc-suppression for flexible power source [J]. Automation of Electric Power Systems , 2021 , 45 ( 20 ): 140 - 147 .
叶远波 , 汪胜和 , 谢民 , 等 . 高阻接地故障时消弧线圈并联小电阻接地的控制方法研究 [J]. 电力系统保护与控制 , 2021 , 49 ( 19 ): 181 - 186 .
YE Yuanbo , WANG Shenghe , XIE Min , et al . Study on the control method of high impedance faults in the neutral via arc suppression coil paralleled with a low resistance grounded system [J]. Power System Protection and Control , 2021 , 49 ( 19 ): 181 - 186 .
喻锟 , 邹豪 , 曾祥君 , 等 . 谐振接地配电网对地绝缘参数双端谐振测量新方法 [J]. 电力系统自动化 , 2020 , 44 ( 12 ): 154 - 161 .
YU Kun , ZOU Hao , ZENG Xiangjun , et al . A novel double-terminal resonant measurement method of insulation-to-ground parameters for resonant grounding distribution network [J]. Automation of Electric Power Systems , 2020 , 44 ( 12 ): 154 - 161 .
陈柏超 , 王朋 , 沈伟伟 , 等 . 电磁混合式消弧线圈的全补偿故障消弧原理及其柔性控制策略 [J]. 电工技术学报 , 2015 , 30 ( 10 ): 311 - 318 .
CHEN Baichao , WANG Peng , SHEN Weiwei , et al . The principle of full compensation arc suppression and flexible control of electromagnetic hybrid Petersen coil [J]. Transactions of China Electrotechnical Society , 2015 , 30 ( 10 ): 311 - 318 .
卓超 , 曾祥君 , 彭红海 , 等 . 配电网接地故障相主动降压消弧成套装置及其现场试验 [J]. 电力自动化设备 , 2021 , 41 ( 1 ): 48 - 58 .
ZHUO Chao , ZENG Xiangjun , PENG Honghai , et al . Arc suppression device with active reduction of grounding fault phase voltage and field test for distribution networks [J]. Electric Power Automation Equipment , 2021 , 41 ( 1 ): 48 - 58 .
曾祥君 , 卓超 , 喻锟 , 等 . 基于接地变压器绕组分档调压干预的配电网主动降压消弧与保护新方法 [J]. 中国电机工程学报 , 2020 , 40 ( 5 ): 1523 - 1534 .
ZENG Xiangjun , ZHUO Chao , YU Kun , et al . A novel method of faults arc extinguishing and feeder protection based on voltage regulating intervention with grounding transformer winding taps for distribution networks [J]. Proceedings of the CSEE , 2020 , 40 ( 5 ): 1523 - 1534 .
薛永端 , 李广 , 徐丙垠 . 利用熄弧后暂态信息测量谐振接地系统的对地电容 [J]. 电工技术学报 , 2020 , 35 ( 7 ): 1521 - 1528 .
XUE Yongduan , LI Guang , XU Bingyin . Measuring method of capacitance to ground in resonant grounding system based on transient information after arc extinguishing [J]. Transactions of China Electrotechnical Society , 2020 , 35 ( 7 ): 1521 - 1528 .
李广 , 薛永端 , 徐丙垠 , 等 . 小电流接地系统接地故障电弧重燃暂态特征分析 [J]. 电力系统自动化 , 2020 , 44 ( 11 ): 189 - 196 .
LI Guang , XUE Yongduan , XU Bingyin , et al . Analysis on arc reignition transient characteristics for grounding fault in non-solidly grounding system [J]. Automation of Electric Power Systems , 2020 , 44 ( 11 ): 189 - 196 .
刘健 , 田晓卓 , 李云阁 , 等 . 主动转移型熄弧装置长馈线重载应用问题分析 [J]. 电网技术 , 2019 , 43 ( 3 ): 1105 - 1110 .
LIU Jian , TIAN Xiaozhuo , LI Yunge , et al . Application analysis of active transfer type arc-extinguishing device under long feeder line and heavy load [J]. Power System Technology , 2019 , 43 ( 3 ): 1105 - 1110 .
ELOMBO A I , HOLTZHAUSEN J P , VERMEULEN H J , et al . Comparative evaluation of the leakage current and aging performance of HTV SR insulators of different creepage lengths when energized by AC, DC+ or DC- in a severe marine environment [J]. IEEE Transactions on Dielectrics and Electrical Insulation , 2013 , 20 ( 2 ): 421 - 428 .
王朋 , 陈柏超 , 周洪 , 等 . 非连续铁心结构磁控消弧线圈的稳态建模与优化设计方法 [J]. 中国电机工程学报 , 2018 , 38 ( 18 ): 5606 - 5614 .
WANG Peng , CHEN Baichao , ZHOU Hong , et al . Steady-state modeling and optimal design method of magnetic controllable Petersen coil with discontinuous core structure [J]. Proceedings of the CSEE , 2018 , 38 ( 18 ): 5606 - 5614 .
王异凡 , 陈国柱 , 张曙 . 一种连续磁阀式消弧线圈及其数学模型 [J]. 电工技术学报 , 2014 , 29 ( 5 ): 239 - 245 .
WANG Yifan , CHEN Guozhu , ZHANG Shu . A continuously magnetic valve arc-suppression coil and its modeling [J]. Transactions of China Electrotechnical Society , 2014 , 29 ( 5 ): 239 - 245 .
曲轶龙 , 董一脉 , 谭伟璞 , 等 . 基于单相有源滤波技术的新型消弧线圈的研究 [J]. 继电器 , 2007 , 35 ( 3 ): 29 - 33 .
QU Yilong , DONG Yimai , TAN Weipu , et al . Research on new type arc-suppression coil based on single-phase active power filter technology [J]. Relay , 2007 , 35 ( 3 ): 29 - 33 .
王崇林 , 刘建华 . 三相五柱式消弧线圈及其自动跟踪补偿原理 [J]. 中国矿业大学学报 , 1999 , 28 ( 5 ): 468 - 472 .
WANG Chonglin , LIU Jianhua . Arc suppression coil with three phases and five columns and its automatic compensation principle [J]. Journal of China University of Mining & Technology , 1999 , 28 ( 5 ): 468 - 472 .
郭谋发 , 游建章 , 张伟骏 , 等 . 基于三相级联H桥变流器的配电网接地故障分相柔性消弧方法 [J]. 电工技术学报 , 2016 , 31 ( 17 ): 11 - 22 .
GUO Moufa , YOU Jianzhang , ZHANG Weijun , et al . Separate-phase flexible arc-suppression method of earth-fault in distribution systems based on three-phase cascaded H-bridge converter [J]. Transactions of China Electrotechnical Society , 2016 , 31 ( 17 ): 11 - 22 .
曾祥君 , 王媛媛 , 李健 , 等 . 基于配电网柔性接地控制的故障消弧与馈线保护新原理 [J]. 中国电机工程学报 , 2012 , 32 ( 16 ): 137 - 143 .
ZENG Xiangjun , WANG Yuanyuan , LI Jian , et al . Novel principle of faults arc extinguishing & feeder protection based on flexible grounding control for distribution networks [J]. Proceedings of the CSEE , 2012 , 32 ( 16 ): 137 - 143 .
曾祥君 , 胡京莹 , 王媛媛 , 等 . 基于柔性接地技术的配电网三相不平衡过电压抑制方法 [J]. 中国电机工程学报 , 2014 , 34 ( 4 ): 678 - 684 .
ZENG Xiangjun , HU Jingying , WANG Yuanyuan , et al . Suppressing method of three-phase unbalanced overvoltage based on distribution networks flexible grounding control [J]. Proceedings of the CSEE , 2014 , 34 ( 4 ): 678 - 684 .
WANG Wen , ZENG Xiangjun , YAN Lingjie , et al . Principle and control design of active ground-fault arc suppression device for full compensation of ground current [J]. IEEE Transactions on Industrial Electronics , 2017 , 64 ( 6 ): 4561 - 4570 .
陈锐 , 周丰 , 翁洪杰 , 等 . 基于双闭环控制的配电网单相接地故障有源消弧方法 [J]. 电力系统自动化 , 2017 , 41 ( 5 ): 128 - 133 .
CHEN Rui , ZHOU Feng , WENG Hongjie , et al . Active arc-suppression method based on double closed-loop control under single-phase grounding faults in distribution networks [J]. Automation of Electric Power Systems , 2017 , 41 ( 5 ): 128 - 133 .
张毅 , 薛永端 , 宋华茂 , 等 . 低阻接地故障有源电压消弧算法性能分析和改进 [J]. 电网技术 , 2017 , 41 ( 1 ): 314 - 321 .
ZHANG Yi , XUE Yongduan , SONG Huamao , et al . Performance analysis and improvement of active voltage arc-suppression algorithm about low resistance grounding fault [J]. Power System Technology , 2017 , 41 ( 1 ): 314 - 321 .
郭谋发 , 蔡文强 , 郑泽胤 , 等 . 计及线路阻抗及负荷影响的配电网柔性电压消弧法 [J]. 电网技术 [ 2021-04-19 ]. DOI: 10.13335/j.1000-3673.pst.2020.1565 http://dx.doi.org/10.13335/j.1000-3673.pst.2020.1565 .
GUO Moufa , CAI Wenqiang , ZHENG Zeyin , et al . Flexible voltage arc-suppression method for distribution networks considering the influence of line impedance and load [J]. Power System Technology [ 2021-04-19 ]. DOI: 10.13335/j.1000-3673.pst.2020.1565 http://dx.doi.org/10.13335/j.1000-3673.pst.2020.1565 .
刘维功 , 薛永端 , 徐丙垠 , 等 . 可适应线路结构动态变化的有源消弧算法 [J]. 电网技术 , 2014 , 38 ( 7 ): 2008 - 2013 .
LIU Weigong , XUE Yongduan , XU Bingyin , et al . An active arc-suppression algorithm adaptable to dynamic structure variation of transmission line [J]. Power System Technology , 2014 , 38 ( 7 ): 2008 - 2013 .
郭谋发 , 游建章 , 林先辉 , 等 . 适应线路参数及负载变化的配电网柔性优化消弧方法 [J]. 电力系统自动化 , 2017 , 41 ( 8 ): 138 - 145 .
GUO Moufa , YOU Jianzhang , LIN Xianhui , et al . Flexible arc suppression optimization method for distribution network adaptable to variation of line parameters and load [J]. Automation of Electric Power Systems , 2017 , 41 ( 8 ): 138 - 145 .
李佳政 , 曾祥君 , 喻锟 , 等 . 基于零序电压调控的配电网不平衡过电压抑制方法 [J]. 电力系统自动化 , 2020 , 44 ( 20 ): 121 - 126 .
LI Jiazheng , ZENG Xiangjun , YU Kun , et al . Suppression method of unbalanced overvoltage in distribution network based on zero-sequence voltage regulation and control [J]. Automation of Electric Power Systems , 2020 , 44 ( 20 ): 121 - 126 .
0
Views
0
下载量
12
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621