XU Bochao.Parameter Correlation Based Parameter Abnormal Point Cleaning Method for Power Station[J].Automation of Electric Power Systems,2020,44(20):142-147.
XU Bochao.Parameter Correlation Based Parameter Abnormal Point Cleaning Method for Power Station[J].Automation of Electric Power Systems,2020,44(20):142-147. DOI: 10.7500/AEPS20191229003.
Parameter Correlation Based Parameter Abnormal Point Cleaning Method for Power Station
Aiming at distinguishing false data and abnormal state points in power plant parameters
a cleaning method based on association rule
density-based spatial clustering of applications with noise (DBSCAN) algorithm and improved Gauss kernel relevance vector machine (RVM) is proposed. Firstly
association rules are introduced to analyze the association among parameters and find out the combination of parameters with strong association. Secondly
the DBSCAN algorithm is used to detect the abnormal point preliminarily
and the cleaning procedure combined with the associated parameters is proposed to distinguish the false data and the system abnormal state points. Finally
RVM is used to clean the false data
and the time cost is reduced by improving the Gaussian kernel space sample point form. Test results show that the cleaning method based on parameter correlation can effectively improve the accuracy and timeliness of cleaning.
LIU Binghan , FU Zhongguang , WANG Pengkai , et al . Big data mining technology application in energy consumption analysis of coal-fired power plant units [J]. Proceedings of the CSEE , 2018 , 38 ( 12 ): 3578 - 3587 .
LENG Xiwu , CHEN Guoping , JIANG Yu , et al . Model construction method of big data application for monitoring and control of smart grid [J]. Automation of Electric Power Systems , 2018 , 42 ( 20 ): 121 - 128 .
HU Yang , QIAO Yilin . Wind power data cleaning method based on confidence equivalent boundary model [J]. Automation of Electric Power Systems , 2018 , 42 ( 15 ): 18 - 23 .
QU Zhaoyang , ZHANG Yijing , WANG Yongwen , et al . Big energy data cleaning model for energy internet based on Spark framework [J]. Electrical Measurement & Instrumentation , 2018 , 55 ( 2 ): 39 - 44 .
SHEN Xiaojun , FU Xuejiao , ZHOU Chongcheng , et al . Characteristics of outliers in wind speed-power operation data of wind turbines and its cleaning method [J]. Transactions of China Electrotechnical Society , 2018 , 33 ( 14 ): 3353 - 3361 .
DAI Jiejie , SONG Hui , YANG Yi , et al . Cleaning method for status data of power transmission and transformation equipment based on stacked denoising autoencoders [J]. Automation of Electric Power Systems , 2017 , 41 ( 12 ): 224 - 229 .
MO Wenxiong , XU Zhong , XIAO Fei , et al . Research on temporal-spatial correlation of power disturbance events based on random matrix theory [J]. High Voltage Engineering , 2017 , 43 ( 7 ): 296 - 303 .
XIE Longjun , LI Li , CHENG Yong , et al . A fault diagnosis method of power transformers by integrated set pair analysis and association rules [J]. Proceedings of the CSEE , 2015 , 35 ( 2 ): 277 - 286 .
TIAN Li , XIANG Min . Abnormal power consumption analysis based on density-based spatial clustering of applications with noise in power systems [J]. Automation of Electric Power Systems , 2017 , 41 ( 5 ): 64 - 70 .
SUN Peng , HUANG Xuyong , GENG Sujie , et al . Dynamic assessment of power transformer status based on real-time monitoring and experimental data [J]. Electric Power Automation Equipment , 2018 , 38 ( 3 ): 210 - 217 .
WANG Yingbo , MA Jing , CHAI Jiajia , et al . Improved association rule mining algorithm based on Hadoop platform [J]. Computer Engineering , 2016 , 42 ( 10 ): 69 - 74 .
YANG Yuewen , HOU Huijuan , YANG Yi , et al . Association rule mining and prediction method for transmission line operation parameters based on Bayesian model [J]. Power System Technology , 2017 , 41 ( 11 ): 260 - 266 .
WANG Guilan , ZHOU Guoliang , ZHAO Hongshan , et al . Fast clustering and anomaly detection technique for large-scale power data stream [J]. Automation of Electric Power Systems , 2016 , 40 ( 24 ): 27 - 33 .
SUN Xiaolei , ZHENG Hua , LI Hui , et al . Bad data identification for leakage reactance parameters of transformer based on improved DBSCAN algorithm [J]. Automation of Electric Power Systems , 2017 , 41 ( 9 ): 96 - 101 .
LI Dong , SONG Yunting , REN Dajiang , et al . Research on islanding configuration and coordination based on coherency identification [J]. Ningxia Electric Power , 2016 ( 4 ): 9 - 17 .
SUN Yi , LI Shihao , CUI Can , et al . Improved outlier detection method of power consumer data based on Gaussian kernel function [J]. Power System Technology , 2018 , 42 ( 5 ): 1595 - 1604 .
WANG Fengtao , LIU Xiaofei , DUN Bosen , et al . Application of kernel auto-encoder based on firefly optimization in intershaft bearing fault diagnosis [J]. Journal of Mechanical Engineering , 2018 , 55 ( 7 ): 58 - 64 .
WU Kun , KANG Jianshe , CHI Kuo , et al . Fault diagnosis method of power transformers using improved multi-class classification algorithm and relevance vector machine [J]. High Voltage Engineering , 2016 , 42 ( 9 ): 3011 - 3017 .
FAN Lei , WEI Zhinong , LI Huijie , et al . Short-term wind speed interval prediction based on VMD and BA-RVM algorithm [J]. Automation of Electric Power Systems , 2017 , 37 ( 1 ): 93 - 100 .
XU Bochao . Applications of separability index of high-dimensional space in rotor diagnosis system optimization [J]. China Mechanical Engineering , 2019 , 30 ( 10 ): 1239 - 1243 .