Design and Implementation of Multi-active Data Synchronization in Analysis and Decision-making Center of New Generation Power Grid Dispatching and Control System
Basic Research|更新时间:2025-06-16
|
Design and Implementation of Multi-active Data Synchronization in Analysis and Decision-making Center of New Generation Power Grid Dispatching and Control System
Automation of Electric Power SystemsVol. 44, Issue 16, Pages: 98-104(2020)
作者机构:
1.南瑞集团有限公司(国网电力科学研究院有限公司),江苏省南京市 211106
2.国电南瑞科技股份有限公司,江苏省南京市 211106
3.智能电网保护和运行控制国家重点实验室,江苏省南京市 211106
作者简介:
基金信息:
National Key R&D Program of China;State Grid Corporation of China
PENG Hui,WU Tao,SHI Haoqiu,et al.Design and Implementation of Multi-active Data Synchronization in Analysis and Decision-making Center of New Generation Power Grid Dispatching and Control System[J].Automation of Electric Power Systems,2020,44(16):98-104.
PENG Hui,WU Tao,SHI Haoqiu,et al.Design and Implementation of Multi-active Data Synchronization in Analysis and Decision-making Center of New Generation Power Grid Dispatching and Control System[J].Automation of Electric Power Systems,2020,44(16):98-104. DOI: 10.7500/AEPS20191213001.
Design and Implementation of Multi-active Data Synchronization in Analysis and Decision-making Center of New Generation Power Grid Dispatching and Control System
The “physical distribution and logical integration” architecture is utilized in new generation power grid dispatching and control system
which requires the analysis and decision-making center deployed in the cloud server to ensure the reliability of the analysis and decision-making function through multi-active way. The synchronization of multi-center data is the key technology among the multi-active centers. Based on the requirement analysis of multi-active centers
the software framework of multi-active data synchronization is proposed and the key technologies are studied such as strong consistency synchronization
final consistency synchronization of data
data recovery after centers faults are resolved
etc. The research results are verified in the prototype system.
XU Hongqiang , YAO Jianguo , NAN Guilin , et al . New features of application function for future dispatching and control systems [J]. Automation of Electric Power Systems , 2018 , 42 ( 1 ): 1 - 7 .
XU Hongqiang , YAO Jianguo , YU Yijun , et al . Architecture and key technologies of dispatch and control system supporting integrated bulk power grids [J]. Automation of Electric Power Systems , 2018 , 42 ( 6 ): 1 - 8 .
ZHAI Mingyu , XU Hongqiang , PENG Hui , et al . Framework and technologies of multi-active service in analysis and decision-making center of new generation dispatching and control system [J]. Automation of Electric Power Systems , 2019 , 43 ( 22 ): 110 - 115 .
LI Xiaoqing . Design and implementation of bank disaster recovery system for“two places and three centers” [J]. Financial Technology Era , 2010 ( 9 ): 60 - 63 .
于俊 . 基于等级的灾备系统模型与方法研究 [D]. 北京 : 北京邮电大学 , 2015 .
YU Jun . Research on model and method of grade based disaster recovery system [D]. Beijing : Beijing University of Posts and Telecommunications , 2015 .
Alibaba Group Double 11 Technical Team . All in double 11 : Alibaba technology evolution and transcendence[M] . Beijing: Publishing House of Electronics Industry , 2017 .
H 3 C. From “two places and three centers” to “distributed multi activities”—the evolution of enterprise multi data center architecture [EB/OL]. [ 2020-04-15 ]. http://www.h3c.com/cn/d_201307/790142_30008_0.htm http://www.h3c.com/cn/d_201307/790142_30008_0.htm .
ZHANG Xugang , LI Donghui , YU Jun , et al . MySQL distributed database cluster based on zookeeper and strong consistency replication [J]. Microcomputer Application , 2016 , 32 ( 1 ): 81 - 84 .
TONG Bin , WANG Feng , LIU Yingbo . Application of Paxos based strong consistency replication in astronomical data storage [J]. Astronomical Research and Technology , 2019 , 16 ( 1 ): 111 - 117 .
XU Jin , HUANG Bo , FENG Jiong . Eventual consistency platform of distributed system based on message communication [J]. Journal of Computer Applications , 2017 ( 4 ): 249 - 255 .
LI Lixin , XIE Qiaoyun , YUAN Rongchang , et al . Optimization analysis and design of power grid dispatching cloud disaster recovery system [J]. Automation of Electric Power Systems , 2012 , 36 ( 23 ): 82 - 86 .