Phase Offset Characteristics of Commutation Voltage for HVDC with Single-phase Grounding Fault
Application Research|更新时间:2025-06-16
|
Phase Offset Characteristics of Commutation Voltage for HVDC with Single-phase Grounding Fault
Automation of Electric Power SystemsVol. 44, Issue 12, Pages: 162-168(2020)
作者机构:
1. 广东电科院能源技术有限责任公司,广东省 广州市 510080
2. 直流输电技术国家重点实验室,南方电网科学研究院有限责任公司,广东省 广州市 510663
3. 华南理工大学电力学院,广东省 广州市 510641
作者简介:
基金信息:
Abstract:
In order to solve the bipolar commissioning problem of high voltage direct current (HVDC) transmission projects while the construction of conventional earth electrodes are not completed, the unconventional earth electrode operation schemes, including in-station deep electrodes and out-station simple electrodes, are introduced. Then the electrical performance of electrodes, human safety, electrode heating, DC bias of transformers and diverting potential are studied. The main conclusions are as follows: in-station deep electrode schemes are technically feasible, but isolating measures should be taken to avoid high induced DC potential of earthing grid endangering the safety of equipment and human, for out-station simple electrode schemes, the step voltage and electrode temperature rise requirements are difficult to meet in monopole operation mode. So unbalanced current control measures should be introduced to ensure the safety of equipment and human near electrodes.
Foundation:This work is supported by National Natural Science Foundation of China;National Natural Science Foundation of China-State Grid Corporation of China Joint Fund Project;State Key Laboratory Project of China Southern Power Grid
HUANG Menghua,FU Chuang,WANG Juanjuan,et al.Phase Offset Characteristics of Commutation Voltage for HVDC with Single-phase Grounding Fault[J].Automation of Electric Power Systems,2020,44(12):162-168.
HUANG Menghua,FU Chuang,WANG Juanjuan,et al.Phase Offset Characteristics of Commutation Voltage for HVDC with Single-phase Grounding Fault[J].Automation of Electric Power Systems,2020,44(12):162-168. DOI: 10.7500/AEPS20191021009.
Phase Offset Characteristics of Commutation Voltage for HVDC with Single-phase Grounding Fault
Asymmetrical faults on the inverter side of the high voltage direct current (HVDC) transmission system will lead to the phase offset of commutation voltage of converter valve
which will cause commutation failures and seriously affect the stable operation of the system. So it is necessary to study the phase offset characteristics of commutation voltage under asymmetric faults. Based on the transient analysis method of the power system
the positive-
negative- and zero-sequence decompositions of the HVDC transmission system under asymmetric faults are carried out
and the calculation formulas for the amplitude and phase of the three-phase voltage on the valve side of the converter transformers for YNy0 and YNd1 wiring are derived
and the maximum deviation of the commutation voltage of the 12-pulsation converter valve under an asymmetric fault is obtained. In addition
the amplitude of the AC bus voltage on the grid side of the converter is calculated
based on MATLAB simulation software
the characteristic variation of commutation voltage offset of converter valve with different types of ground fault impedance are analyzed. The PSCAD/EMTDC electromagnetic transient simulation results prove the correctness of the influence characteristics of commutation voltage offset analyzed in this paper.
关键词
Keywords
references
XUE Ying , ZHANG Xiaoping , YANG Conghuan . Elimination of commutation failures of LCC HVDC system with controllable capacitors [J]. IEEE Transactions on Power Systems , 2016 , 31 ( 4 ): 3289 - 3299 .
HUANG Shaofeng , SHEN Hongming , FEI Bin , et al . Effect of commutation failure on the distance protection and the countermeasures [J]. IET Generation , Transmission & Distribution , 2015 , 9 ( 9 ): 838 - 844 .
AIK D L H , ANDERSSON G . Voltage stability analysis of multi-infeed HVDC systems [J]. IEEE Transactions on Power Delivery , 1997 , 12 ( 3 ): 1309 - 1318 .
THIO C V , DAVIES J B , KENT K L . Commutation failures in HVDC transmission systems [J]. IEEE Transactions on Power Delivery , 1996 , 11 ( 2 ): 946 - 957 .
HANSEN A , HAVEMANN H . Decreasing the commutation failure frequency in HVDC transmission systems [J]. IEEE Transactions on Power Delivery , 2002 , 15 ( 3 ): 1022 - 1026 .
RAHIMI E , GOLE A M , DENVIES J B , et al . Commutation failure analysis in multi-infeed HVDC systems [J]. IEEE Transactions on Power Delivery , 2011 , 26 ( 1 ): 378 - 384 .
WANG Feng , LIU Tianqi , ZHOU Shengjun , et al . Mechanism and quantitative analysis method for HVDC commutation failure resulting from harmonics [J]. Proceedings of the CSEE , 2015 ,
LI Chenghao , LIU Chang , ZHANG Zhen’an , et al . Analysis of commutation failure in HVDC power transmission system considering prediction control of commutation failure and initial fault angle [J]. Automation of Electric Power Systems , 2018 , 42 ( 3 ): 56 - 63 .
WANG Feng , LIU Tianqi , LI Xingyuan , et al . Commutation failure analysis considering DC current rise and AC voltage drop speed [J]. Automation of Electric Power Systems , 2016 , 22 ( 25 ): 111 - 117 .
CHEN Guangqin , FU Chuang , ZHANG Yongjun . Detection method of HVDC commutation failure based on characteristic of valve current [J]. Automation of Electric Power Systems , 2018 , 42 ( 23 ): 128 - 136 .
KRISTMUNDSSON G M , CARROLL D P . The effect of AC system frequency spectrum on commutation failure in HVDC inverters [J]. IEEE Transactions on Power Delivery , 2002 , 5 ( 2 ): 1121 - 1128 .
OTTOSSON N , KJELLIN L . Modular back-to-back HVDC , with capacitor commutated converters (CCC) [C]// Seventh International Conference on AC-DC Power Transmission, November 28-30 , 2001 , London , UK .
LIU Yuchao , GUO Chunyi , XU Weihua , et al . A control method to reduce commutation failure probability in HVDC power transmission [J]. Power System Technology , 2015 , 39 ( 1 ): 76 - 82 .
LI Ruipeng , LI Yongli , CHEN Xiaolong . A control method for suppressing the continuous commutation failure of HVDC transmission [J]. Proceedings of the CSEE , 2018 , 38 ( 17 ): 5029 - 5042 .
WANG Zimin , WANG Juanjuan , FU Chuang , et al . Individual phase control of high voltage direct current based on single-phase locked loop [J]. Automation of Electric Power Systems , 2018 , 42 ( 21 ): 160 - 168 .
WANG Juanjuan , WANG Zimin , XUAN Xiaocong , et al . Extinction angle control based on predictive calculation and its improvement [J]. Power System Technology , 2018 , 42 ( 12 ): 3985 - 3991 .
WANG J , HUANG M , FU C , et al . A new recovery strategy of HVDC system during AC faults [J]. IEEE Transactions on Power Delivery , 2019 , 34 ( 2 ): 486 - 495 .
WANG Juanjuan , WEN Zhaoxin , FU Chuang , et al . HVDC fault recovery strategy based on commutation voltage phase detection [J]. Power System Technology , 2019 , 43 ( 10 ): 3504 - 3514 .
DING Wanglin , LUO Jian , LIU Qiang . Effect of zero sequence current on star-delta vector transformation of digital transformer differential protection [J]. Automation of Electric Power Systems , 2004 , 28 ( 5 ): 56 - 58 .
WANG Juanjuan , HUANG Menghua , FU Chuang . Research on operational characteristics and recovery strategy of HVDC under AC fault [J]. Proceedings of the CSEE , 2019 , 39 ( 2 ): 514 - 523 .