the stability and interference suppression performance of the grid-connected inverter
using the traditional robust H∞ control method
are often affected by the weak grid characteristics of the power grid. In order to enhance the adaptability of grid-connected inverters to grid impedance changes
this paper presents an improved H∞ control method for grid-connected inverters which is suitable for weak grids. A single-phase grid-connected inverter is used as an example to establish a robust H∞ control model for a grid-connected inverter under a weak grid and to prove that the weak grid characteristics will cause the system parameter
control input parameter and interference input parameter are perturbed
which affects the stability and interference suppression performance of the system. In order to overcome the influence of weak grid characteristics and improve the stability and interference suppression performance of the system
an improved H∞ control method for grid-connected inverter in weak power grid is proposed. In this method
indirect control is introduced to dynamically adjust the voltage of the common connection point and to eliminate the parameter perturbation of the control system
which makes the grid-connected inverter adaptable to the weak grid. Finally
the rationality and validity of the theoretical analysis and the improved H∞ control method are verified by the experiments.