In the time synchronization process of smart substation
there is one noteworthy problem that the delay jitter of paths in the time-synchronization communication network may cause the degradation of the synchronization precision. Therefore
this paper proposed an IEEE 1588 synchronization time-delay optimization method. Firstly
this paper analyzes the course of the synchronizations error caused by delay jitter of paths in the environment of smart substation
which aims to implement the quantitative analysis of the synchronization error mechanism. Secondly
based on the framework of IEEE 1588 protocol
the proposed method is depicted to operate the second time’s compensation using an optimal estimation of delay jitter of paths
which is calculated by a time-delay extending measurement mechanism to compress the synchronization’s influence from delay jitter of paths. Finally
the proposed method is verified by an experiment based on the typical end-to-end transparent clock synchronization mode of IEEE 1588 protocol in smart substation. The simulation results show that the proposed method may achieve better time synchronization performance in terms of precision and stability for slavery clocks in smart substation.