In a linear optical current transducer(OCT)based on the radial grating polarizer detection
the faraday rotation angle is converted into synchronous rotation of a circular facula. Then
a charge coupled device camera(CCDC)is utilized to position the dark stripe of the facula to achieve a real time current measurement. The linear OCT overcomes some issues in the OCT of traditional light intensity detection mode
such as small dynamic measurement range
nonlinear detection
light intensity dependence
linear birefringence and temperature drift etc. However
the linear OCT still has some shortcomings
such as high cost
low resolution
big algorithm error
and not being capable of meeting 0. 2S accuracy class
especially in small current measurement. In order to fix these problems
a four-quadrant detector is employed to sense the rotation angle of the circular facular with the advantages of low cost
simple algorithm
high-resolution and high-accuracy. It has been verified that the resolution of measurement is increased nearly 100-fold by theoretical analysis and experimental derivation in the range of ±40°of the faraday rotation angles. The accuracy is improved from 0. 5% class to 0. 2S
and the cost of picture detection unit is reduced by more than 95%.