The amplitude of each frequency component of sub-module capacitors ripple voltages is inversely proportional to its frequency in modular multilevel matrix converters(M3C). When the output-input frequency ratio approaches 1/3 under the low-frequency operating conditions
M3C will hardly work properly on account of too high a ripple voltage amplitude of difference frequency between the input frequency and triple output frequency
blocking the continuous suppression of doubling output frequency ripple voltage. This paper presents a control scheme based on the decoupled hierarchical capacitors voltages control and arm current independent control. The doubling output frequency ripple voltage instantaneous power is directly controlled by the outer loop feedback. The continuous operating frequency range is expanded because of the elimination of discontinuous points nearby or the frequency ratio 1/3 by means of current reconstruction. Finally
the OPAL-Rtlab experiments results have verified the control scheme. This work is supported by National Natural Science Foundation of China(No. 51541708).
Interline DC Power Flow Controller with Fault Current Limiting Function and Its Control Method
Average Dynamic Phasor Modeling and Stability Analysis of Multi-voltage-level DC Distribution Network
Control Strategy of M3C Matrix Converter System Applied to AC-AC Transformation
基于子模块瞬时功率跟随模块化多电平矩阵变换器控制策略
模块化多电平矩阵变换器低频控制方法
Related Author
Ning XIE
Mingsheng LYU
Chaoqun TUO
Qianming XU
Xinyu HUANG
Dexin LI
Guoqing LI
Long CHENG
Related Institution
China Southern Power Grid Company Limited
National Electric Power Conversion and Control Center, Hunan University
Electric Power Research Institute of State Grid Jilin Electric Power Co., Ltd.
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education (Northeast Electric Power University)
Zhejiang Engineering Laboratory of Regional Energy Internet Technology, Hangzhou Dianzi University