海上双馈风电机组开路故障容错重构技术
摘要
为了降低海上风电场的度电成本
避免可及性差导致的维护困难
提出一种海上双馈风电机组开路故障的容错方法。首先
根据开路故障的位置特点给出不同的硬件重构方案。然后
针对转子侧变流器单相开路故障
优化故障后的三相四开关变频器调制信号
同时加入直流电压偏差
补偿故障引起的直流电容电压波动。仿真与实验结果表明
发生单相开路故障后
通过软、硬件容错技术可实现无冗余配置下的非备份式容错运行
提高机组的可用率。
Abstract
In order to reduce per kilowatt hour cost in offshore wind farms and avoid maintenance difficulties caused by accessibility
a fault-tolerant method for wind turbines based on doubly-fed induction generator(DFIG)is put forward. First of all
different hardware reconfiguration schemes are given according to the different locations and characteristics of the open-circuit faults. Then
when single-phase open-circuit fault occurs in machine-side converter
three-phase four-switch inverter modulation signals are optimized and the DC voltage deviation is added at the same time to compensate capacitor voltage fluctuation. Simulation and experimental results show that when single-phase open-circuit fault of DFIG-based wind turbines is occurred
backup-free fault-tolerant operation is realized without redundancy by hardware reconfiguration and software fault tolerance
and the availability ratio of DFIG-based wind turbines is also improved. This work is supported by Shanghai Science and Technology Innovation Action Plan(No. 16DZ1203504).