Automation of Electric Power SystemsVol. 38, Issue 22, Pages: 103-107(2014)
作者机构:
强电磁工程与新技术国家重点实验室, 华中科技大学,湖北省,武汉市,430074
作者简介:
基金信息:
DOI:
CLC:
Published:2014
稿件说明:
移动端阅览
LOU Lingjiao. [J]. Automation of electric power systems, 2014, 38(22): 103-107.
DOI:
LOU Lingjiao. [J]. Automation of electric power systems, 2014, 38(22): 103-107.DOI:
发电机静止励磁系统故障快速保护
摘要
励磁系统是同步发电机的重要组成部分
其安全对发电机的正常运行至关重要。结合对某大型电厂机组励磁系统事故案例的分析
指出目前励磁变压器保护配置缺乏可依据的规程
导致出现配置方案无法对发电机静止励磁系统整流主回路故障进行快速保护的问题。为此
提出一种可供选择的发电机静止励磁系统的快速保护方案
并在仿真分析的基础上给出了该保护的整定方法和安装位置。该保护方案能够快速对励磁系统故障做出反应
避免造成励磁系统的损坏
且实施简单
易于推广应用。
Abstract
The excitation system is an important component of synchronous generator whose security is essential for the normal operation of the generator. According to an analysis of excitation system accidents occurring in a large power plant
it is noted that for lack of rules to go by for excitation transformer protection configuration
current protection schemes are not able to respond quickly to the main circuit fault of generator static excitation system. Therefore
a fast protection scheme for generator static excitation system is put forward
and the protection setting method and installation location are given on the basis of simulation. The protection scheme is able to quickly respond to the excitation system failure to avoid serious damage to the system and its principle is simple and easily applied.