The ability of absorbing the disturbance of wind power generation has become a bottleneck to the development of the wind power. Because of the lower load response rate
traditional thermal power units cannot meet the requirement. The pipe line
heat exchanger and radiator in the heat supply network of heat supply units have huge capacity of thermal storage
which can be used to improve the load response rate within a short time. Based on the idea of experimental verification
by nonlinear multi scale decomposing of automatic generation control (AGC) load order
the load order of heat supply units is constructed. According to the simplified nonlinear dynamic model of typical heat supply units
the optimization control scheme for units is designed. The scheme can take full advantage of the thermal storage in the heat supply network
which can improve the load response rate of the units drastically and can compensate the stochastic disturbance of wind power generation without the influence on the heat consumer.
Regulation Performance-oriented Bi-level Optimal Configuration Strategy of Hybrid Energy Storage for Thermal Power-Energy Storage Frequency Regulation
Optimal Control of Electric Vehicle Cluster Participating in Frequency Regulation Market Considering User Preferences
Reliable Regulation Capability Extraction Strategy for Cluster Electric Heating Load Considering Average Heating Demand
Related Author
FANG Yan
LI Jinghua
LAN Fei
XIE Lingling
LAI Yening
YAN Gangui
SHA Qianli
LI Junhui
Related Institution
Guangxi Key Laboratory of Power System Optimization and Energy Technology (Guangxi University)
State Grid Electric Power Research Institute (NARI Group Corporation)
Key Laboratory of Modern Power System Simulation and Control & Renewable Energy Technology, Ministry of Education (Northeast Electric Power University)
Research Center for Photovoltaic Systems Engineering of Ministry of Education, Hefei University of Technology