计及关键支路的输电断面自动确定方法
摘要
随着电力系统规模不断增大以及系统结构和负荷组成趋于复杂化
系统运行控制的难度随之增加。 在此背景下
国内外提出了以输电断面作为系统运行的安全特征量并以此来提高系统运行控制的效率。这样
如何适当识别/确定输电断面就成了一个重要问题。然而
现有的输电断面识别方法未能充分考虑系统分析和监控的实际需要。例如
为了保证系统运行安全
调度人员需要及时而准确地知道各个分区之间的联络断面中存在最大过载风险的支路
从而结合其安全运行状况制定控制目标和策略
而现有的输电断面识别方法不具备这样的功能。在此背景下
针对大规模电力系统运行分析和控制的实际需要
提出了一种能够考虑制约输电能力关键支路的输电断面自动识别方法。首先
根据网络结构和潮流状态自动搜索出系统中存在的断面形式; 然后
在断面输电极限分析过程中
识别影响断面输电能力的关键支路且将其返回作为断面实际监控对象
并给出相应的控制对象和策略。其中
控制对象为电压等级高的支路中的潮流
而控制目标则为搜索得到的关键支路潮流不过载。最后
通过在广东省电力系统的应用验证了文中所提出的模型和方法的合理性与有效性。
Abstract
In large scale power systems
the specially defined transmission section could be used to measure the security levels of actual system operating states. However
existing approaches for the automatic discovery of a transmission section do not properly consider the critical branch with the minimum security margin
and hence the accuracy of the security level evaluation cannot be guaranteed. Given this background
a new method of automatically discovering transmission sections
with the critical branch taken into account
is developed for assisting system operators to find more reliable and accurate control strategy. First
a set of transmission sections is obtained by employing the network topology and real-time power flow. Next
a repeated power flow based approach is used to evaluate the maximum transmission capability of each transmission section
and at the same time the critical branch is identified. Then
the branches in a transmission section are adjusted to ensure the critical branch is included
and a control strategy could thus be obtained for ensuring the security of the power system concerned. The effectiveness of the proposed method is demonstrated by Guangdong provincial power system.